Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Daikin Heat Pump: Check thermistor, EEV coil and solenoid valve coil resistance (S-26)

Updated · by Aurora Star Tech Inc.

Check thermistor, EEV coil and solenoid valve coil resistance (S-26) on a Daikin heat pump: Outdoor units and EEV indoor units use thermistors for outdoor air, coil, liquid, discharge, defrost, suction, indoor gas and indoor liquid. The EEV and solenoid valves are coils that also have a resistance check.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Outdoor units and EEV indoor units

Common causes of check thermistor, eev coil and solenoid valve coil resistance (s-26)

  • Open, shorted or out-of-range thermistor
  • Open or shorted EEV coil
  • Open or shorted solenoid valve coil

How to fix check thermistor, eev coil and solenoid valve coil resistance (s-26): step by step

  1. Disconnect power to all equipment.
  2. Disconnect the thermistor connector from the control board.
  3. Connect an ohmmeter across the thermistor terminals and compare with the thermistor resistance table. Replace if open, shorted or out of range.
  4. To check the EEV coil, disconnect the EEV cable from the control board and read resistance between the connector pins. The reading should be 40 to 50 Ω.
  5. To check the solenoid valve coil, disconnect the cable from the control board and read resistance between the connector pins. The reading should be 1,480 to 1,820 Ω.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Daikin Heat Pump codes

Source: Daikin SiUS612209EA service instructions, p. 21. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service