Daikin General: Dust collection filter replacement procedure
Dust collection filter replacement procedure on a Daikin general: Full removal and install sequence for the dust collection filter and the filters around it.
Applies to: Dust collection filter, carbon filter
How to fix dust collection filter replacement procedure: step by step
- Unplug the unit and remove the water tank (p. 15).
- Remove the humidifying tray (p. 13).
- Remove the filter fixing unit (p. 14).
- Remove the carbon filter by holding its side and pulling it out.
- Lift the tag on the dust collection filter, hold the bottom and pull it out.
- Fit the new dust collection filter. If it is hard to seat, hold it down while installing. The side with the tag and marking is the front, with the arrow pointing up.
- Attach the carbon filter (p. 14).
- Attach the filter fixing unit (p. 14).
- Attach the humidifying tray (p. 28).
- Install the water tank (p. 15).
If the unit shows an error code, look it up: Daikin General codes
Source: Daikin MCKB70YSAU operation manual, p. 31. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.