Weil-McLain Boiler: Zoning with circulators, three space heating zones

Updated · by Aurora Star Tech Inc.

Zoning with circulators, three space heating zones on a Weil-McLain boiler: Three thermostat zones with circulators and no DHW. Thermostats are wired to P11-4/5, P15-1/2 and P15-3/4, with circulators on P2. All three inputs default to PRIORITY 2.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: SF1000L/R, SF1500L/R, SF2000L/R

How to fix zoning with circulators, three space heating zones: step by step

  1. Review the 120 VAC output wiring (p. 49) and 24 VAC input wiring (p. 53).
  2. Wire the thermostats to P11-4/5, P15-1/2 and P15-3/4.
  3. Wire the circulators to the P2 outputs.
  4. During the Wizard, or in the PRIORITY 2 menu, choose the space heating system type that matches the system.
  5. Keep the factory default settings unless the system needs a change.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: SlimFit Series 2 Boiler Manual 550-100-561/1225, p. 60. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.