Updated · by Aurora Star Tech Inc.

Provide access to the boiler air inlet filter on a Weil-McLain boiler: The boiler air inlet filter must stay reachable for periodic inspection and cleaning. Use an 8 in capped tee or route the air piping so it can be disconnected from the boiler air connection. Use only the air piping materials listed in the manual's approved materials figure.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Direct vent installations, sidewall and vertical

How to fix provide access to the boiler air inlet filter: step by step

  1. Install an 8 in capped tee on the air line, oriented so the cover is on the same side as the heat exchanger cleanout cover, or arrange the air piping so it disconnects easily.
  2. If using 6 in air piping, add a vent/air maker's reducer on top of the 8 in tee.
  3. Do not use a 6 in tee.
  4. Use only the approved air piping materials listed in the manual.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Weil-McLain Boiler codes

Source: Weil-McLain SlimFit Series 2 boiler manual, p. 40, p. 42. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.