Beckett Boiler: NX burner: oil supply rules (pump seal leaks, air in line, plugged nozzle)
NX burner: oil supply rules (pump seal leaks, air in line, plugged nozzle) on a Beckett boiler: Most NX oil-side problems come from the supply piping. Check it against these rules.
Applies to: Beckett NX burner with GeniSys 7505 primary control on Weil-McLain Ultra Oil UO-3, UO-4, UO-5 (CV and DV)
Common causes of nx burner: oil supply rules (pump seal leaks, air in line, plugged nozzle)
- Bypass plug in a one-pipe system (blows the pump seal)
- Inlet pressure over 3 psig on gravity feed
- Valve installed in the return line
- Compression fittings or Teflon tape pieces in the line
- Lift over 8 ft on a one-pipe system
- Dirty oil plugging a small nozzle
How to fix nx burner: oil supply rules (pump seal leaks, air in line, plugged nozzle): step by step
- One-pipe: no bypass plug. Two-pipe: bypass plug installed.
- Oil pressure at the burner inlet must not go over 3 psig. Install a pressure limiting device per NFPA 31.
- Gravity feed: needs an anti-siphon valve in the supply line, or solenoid valve 2182602U in the pump-to-nozzle line, as backup oil shut-off.
- No valves in the return line.
- Tank more than 8 ft below the burner: two-pipe system, maybe a two-stage pump (check the pump maker's lift charts).
- Use heavy wall copper with flare fittings only. No compression fittings. No Teflon tape; use oil-resistant pipe dope.
- Two fusible-handle shutoff valves: one at the tank, one near the burner ahead of the filter.
- Filter of 50 micron or finer near the burner. Below 0.75 GPH, add a 10 micron (or finer) secondary filter near the burner with a 50 micron primary near the tank.
If the unit shows an error code, look it up: Beckett Boiler codes
Source: Beckett NX Burner Manual for Weil-McLain Ultra Oil boilers (W-M 550-141-996/0321), Installing the oil tank and supply system p.8-9. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.