Beckett Boiler: NX burner: cad cell resistance check
NX burner: cad cell resistance check on a Beckett boiler: The NX has a small air tube and a throttle cup with small sight windows, so less light reaches the cad cell and the reading is often higher than on older burners. Check it before blaming the control.
Applies to: Beckett NX burner with GeniSys 7505 primary control on Weil-McLain Ultra Oil UO-3, UO-4, UO-5 (CV and DV)
Common causes of nx burner: cad cell resistance check
- Dirty cad cell lens
- Soot or oil film on the throttle cup sight windows
- Damaged or scratched sight window
- Cad cell going bad
How to fix nx burner: cad cell resistance check: step by step
- Read the resistance with flame on: GeniSys display module 52067U or Contractor Tool 52082U, or unplug the cad cell leads at the control and use a meter.
- 0 to 1600 ohms with flame is normal. From 1600 ohms up to the lockout point is the limited range: clean or fix before it starts locking out.
- Power off. Clean the cad cell lens.
- Clean the throttle cup sight windows with a soft cloth and degreaser. Do not scratch, puncture or remove them. If a window is damaged, replace the nozzle line assembly with one that has a windowed throttle cup.
- Recheck the reading with the burner cover installed.
If the unit shows an error code, look it up: Beckett Boiler codes
Source: Beckett NX Burner Manual for Weil-McLain Ultra Oil boilers (W-M 550-141-996/0321), Cad cell resistance indicator p.12; cad cell note p.15; maintenance p.17. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.