Daikin Air Handler: Measure two-piece unit external static (S-203A)

Updated · by Aurora Star Tech Inc.

Measure two-piece unit external static (S-203A) on a Daikin air handler: A two-piece unit is an EEV cased coil with a gas furnace or modular blower. External static is measured at the furnace or modular blower.

Homeowner with a air handler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: EEV cased coil with gas furnace or modular blower

Common causes of measure two-piece unit external static (s-203a)

  • Restricted return or supply duct
  • Closed dampers or registers
  • Dirty filter or electronic air cleaner loading

How to fix measure two-piece unit external static (s-203a): step by step

  1. With clean filters in the indoor unit, measure return static at the inlet of the gas furnace or modular blower (negative pressure).
  2. If a filter is in the return, measure between the filter and the furnace or blower.
  3. Measure supply static at the outlet of the gas furnace or modular blower (positive pressure).
  4. Add the two absolute readings for total external static. Include any electronic air cleaner in the readings.
  5. Use the airflow chart for the gas furnace or modular blower to find CFM at the measured static.
  6. If total static is outside the minimum or maximum, check for closed dampers, registers, and undersized or oversized poorly laid out ductwork.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Daikin Air Handler codes

Source: Daikin SiUS612209EA service instructions, p. 24. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.