Daikin Air Handler: ECM control/end bell and motor winding checks
ECM control/end bell and motor winding checks on a Daikin air handler: Tests the control/end bell and motor windings after the blower assembly is removed. The motor contains capacitors that hold a charge for several minutes.
Applies to: Emerson ECM blower in indoor air handler
Common causes of ecm control/end bell and motor winding checks
- Cracked or broken NTC thermistor in the control/end bell
- Bulging or swollen capacitors
- Low resistance in the control/end bell connector
- Unequal, open or shorted motor windings
How to fix ecm control/end bell and motor winding checks: step by step
- Disconnect power and wait 5 minutes for the capacitors to discharge.
- Disconnect the motor control and motor power harnesses, then remove the blower assembly.
- Remove the three screws holding the control/end bell to the motor and disconnect the 3-circuit harness.
- Inspect the NTC thermistor. Replace the control/end bell if cracked or broken.
- Inspect the large capacitors. Replace the control/end bell if any are bulging or swollen.
- Check resistance between each terminal of the 3-circuit connector. Replace the control/end bell if resistance is lower than 1 MΩ.
- For the motor, measure resistance between each phase winding with an ohmmeter. Replace the motor if the readings are unequal, open or shorted.
- Measure resistance between each phase winding and the motor shell. Replace the motor if any winding is shorted to the shell.
- Reassemble in reverse order and replace the blower assembly in the air handler or modular blower.
If the unit shows an error code, look it up: Daikin Air Handler codes
Source: Daikin SiUS612209EA service instructions, p. 19. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.