Service & test modes: Water Heater tips
Short, practical technician tips on service & test modes for water heater. Check each one against the manual for your exact model before acting.
Enter setting mode on cascade unit display
Daikin · Cascade unit push-button display
Hold the page break button for over 5 seconds in normal mode to get into setting mode. BS1 changes mode, BS2 changes values, BS3 confirms.
- Press and hold BS1 for more than 5 seconds from normal mode.
- Use BS2 to change values and BS3 to confirm.
- Press BS1 once to leave setting mode and return to normal mode.
Diagnostics button (installers only)
Navien · Indoor models with front panel
The Diagnostics button is for installers only and is not for normal user operation.
Evaporator fan test
Navien · NWP500 series
The fan runs and then stops for 20 seconds. The current RPM is shown on the front panel.
- Enter Test Mode and select Evaporate Fan.
- Watch the RPM value on the front panel during the run.
- Confirm the fan reaches the expected speed and stops.
Leak detection shut-off valve test
Navien · NWP500 series with leak detection shut-off valve
The valve is driven to full open (0%) and then full close (100%). The valve returns to its prior status afterward.
- Enter Test Mode and select Leak Detection System.
- Check the feedback during the procedure.
- Confirm the valve reaches full open and full close, then returns to its latest status.
Open Status Information menu
Navien · NWP500-50, NWP500-65, NWP500-80
Shows hot water, heat pump, heating element and recirc pump readings.
- Press and hold Menu for more than 5 seconds.
- Select Status Information.
- Use Up/Down to scroll, OK to open an item, Back to return.
Read monthly EMS operation data
Navien · NWP500-50, NWP500-65, NWP500-80
Shows heat pump run time, heating element run time and power use for the month.
- Press and hold Menu for more than 5 seconds.
- Select EMS Data.
- Scroll with Up/Down and press OK to view HP Operation Time, HE Operation Time or Power Consumption.
Recirculation pump test
Navien · NWP500 series with Navien recirculation pump kit
You can turn the recirculation pump on or off from the test menu. The test ends after 5 minutes if the pump does not run. A forced run stops if no flow is detected for 30 seconds.
- Enter Test Mode and select Recirc Pump Kit.
- Press Up or Down to turn the pump on or off.
- If no flow is detected for 30 seconds while forced on, expect the pump to de-energize to prevent damage.
System air removal using TEST MODE pump cycle
Navien · NPE, NPE-A2/S2 and NHW700-A water heaters with H2Air
TEST MODE cycles the internal pump to purge air from the combination system piping through the pump air vent or installed air removal accessories.
- NPE and NPE-A2/S2: press the [Diagnostic] and [Back] buttons together to enter the Special Operations menu.
- NHW700-A: press and hold the [Diagnostic] button for 5 seconds to enter the Special Operations menu.
- Select TEST MODE, then select PUMP to cycle the internal pump.
- Run the cycle until air is removed from the system piping.
Test the recirculation pump kit
Navien · ComfortCirc recirculation pump kit
Runs the recirculation pump on and off so you can check it. The control status and flow rate show on the front panel.
- Press and hold the Menu and Back buttons together for more than 5 seconds, then select Test Mode.
- Select Recirc Pump Kit from the Test Mode menu.
- Use Up or Down to switch the pump on or off.
- If the pump does not run for 5 minutes, the test ends automatically.
- Press Back to return to the previous screen.
Viewing basic information (indoor models)
Navien · NPN indoor models
The information view shows flow rate and inlet and outlet water temperatures.
- Press the Information button.
- Press the + or – buttons to switch between the information types: flow rate in GPM, hot outlet temperature (OUT) and cold inlet temperature (IN).
- Press the Reset button to exit information mode.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.