Reset & cancel: Furnace tips (part 2 of 2)

Updated · by Aurora Star Tech Inc.

Short, practical technician tips on reset & cancel for furnace. Check each one against the manual for your exact model before acting.

Reset a soft lockout (R95P)

Rheem · R95PA040, 060, 070 (1317MSA), R95PA085, 100 (1521MSA), R95PA115 (1524MSA); (-)95P series

Soft lockouts can be cleared by cycling the heat call or power. A 1-hour lockout also resets on its own after one hour; a hard lockout (code 93) needs a power reset; code 61 hard lockout can be reset by cycling the heat call.

  1. Cycle the heat call off for 2 to 20 seconds, or cycle power
  2. Code 93 hard lockout: cycle power

Reset the overtemperature safety switch

Rheem · All 96V and 96MDV series furnaces

The overtemperature switches sit in the burner compartment and trip when combustion air is inadequate. A tripped switch must be reset by hand, but only after the cause is cleared.

  1. Find the cause of the overtemperature trip, usually inadequate combustion air.
  2. Correct the cause.
  3. Press the manual reset on the switch in the burner compartment.

Burner box temperature limit reset

Trane · All models

A manual reset temperature limit is on the burner box and opens the gas circuit on overheat.

  1. If the limit trips, find and correct the overheat cause.
  2. Reset the manual limit on the burner box.
  3. For full shutdown, set the main gas valve switch to OFF and disconnect electrical supply.

Burner box temperature limit shutdown

Trane · AUH1B furnaces

The manual reset limit on the burner box opens and shuts off gas flow when temperature is excessive.

  1. Check vent and combustion air inlet terminations for blockage.
  2. Clear any blockage, then press the reset button.
  3. If there is no blockage, have a qualified servicer reset the limit.

Reset after lockout

Trane · AUH1B furnaces

The control stays locked out until it is reset manually.

  1. Turn system power off, on, off, then on again within 30 seconds.
  2. Reset can be done at the unit power source or at the thermostat.
  3. If the sequence is not completed within 30 seconds, it will not reset.

Reset the control to factory defaults

Trane · S8V2, S8B1, S8X1, S8X2

Holding Menu and Option together at idle resets all menu values to factory defaults; the display flashes FD three times to confirm.

  1. Make sure the display is in idle (IdL)
  2. Hold Menu and Option together for 15 seconds, then release
  3. FD flashes three times
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.