Short, practical technician tips on other for water heater. Check each one against the manual for your exact model before acting.

Limits on pumped liquid and use location

Navien · ComfortCirc recirculation pump

The pump is for indoor use only and is not tested for pool or marine areas. It is only for domestic hot water with clean, thin, non-aggressive liquid with no solids, fibers or mineral oils. Water must stay between 36°F and 140°F and up to 145 psi, depending on the variant. Never use it to move flammable liquids.

Outdoor temperature sensor connection

Navien · H2Air outdoor temperature sensor

The outdoor sensor is supplied in the kit. Use 18 gauge thermostat wire and keep the sensor out of direct sunlight.

  1. Insert the exposed wire into the sensor terminal.
  2. Tighten the terminal screw with a screwdriver.
  3. Use 18 gauge thermostat wire for the sensor connection.
  4. Do not mount the sensor in direct sunlight.

Pre-connection checks

Navien · NWP500 series

Check the layout before connecting water lines so the T&P valve, discharge pipe, and condensate line all have room.

  1. Keep the T&P relief valve away from electrical parts.
  2. Confirm room for the T&P discharge pipe.
  3. Confirm room for the condensate drain tubing.
  4. Keep at least 6 in (152 mm) of clearance at the front for maintenance.

Protect the thermocline tube and use approved piping

Navien · NWP500 series

A damaged thermocline tube in the supply or outlet pipe can change water temperature. Use piping and sealants approved for potable water.

  1. Check that the thermocline tube inside the supply and hot outlet pipes is not damaged.
  2. Use pipe materials and sealants approved for potable water.
  3. Confirm suitable pipe material with local plumbing officials.

Recirculation may increase heat pump water heater run time

Navien · Heat pump water heater with ComfortCirc recirculation

Adding a recirculation system to a heat pump water heater can make the water heater cycle on more often.

  1. Tell the owner to expect more frequent heat pump water heater operation after recirculation is added.

Recirculation preheating icon behavior

Navien · NPN non-condensing and NPE-A2/S2 condensing water heaters

The preheating icon shows differently depending on the water heater connected. With non-condensing NPN units it flashes continuously during recirculation. With condensing NPE-A2/S2 units it stays on steadily.

  1. Start recirculation as usual.
  2. If an NPN unit is connected, expect the preheating icon to flash continuously.
  3. If an NPE-A2/S2 unit is connected, expect the preheating icon to stay on.

Recirculation system configurations and pump control

Navien · ComfortCirc recirculation pump

The ComfortCirc supports a dedicated return line or a shared return line that uses the optional NaviCirc. It has built-in temperature and flow sensors. Settings can be made in the NaviLink app, or on the front panel of a connected Navien heat pump water heater, which can control the pump to reduce energy loss and follows CTA-2045 demand response. Wired On-Demand uses the optional HotButton.

Remote controller buttons and LED

Navien · NR-21DU remote controller

Power button turns the controller on or off. Up and Down buttons change temperature or value. OK button confirms. Lock button locks the other buttons. Preheat&Timer button opens timer settings and turns recirculation on. LED: green means normal mode, red means an error has occurred.

Remote controller indicators (outdoor models)

Navien · NPN outdoor models with remote controller

LED: green means normal mode, red means an error has occurred. Display shows current time, set temperature, timer set, recirculation mode, hot water in use, operation in progress, lock status and error codes.

Removing the battery protective film

Navien · NWP500-50, NWP500-65, NWP500-80

The battery protective film on the side of the front panel must be removed after installation and before the heater is connected to power.

  1. Complete the installation.
  2. Remove the battery protective film from the side of the front panel.
  3. Only then connect power.

Replace the front panel battery

Navien · NWP500-50, NWP500-65, NWP500-80

Do not recharge or impact the battery. The clock may need to be set again after replacement. Replacement is recommended every five years.

  1. Remove the battery from the side of the front panel.
  2. Install the new battery.
  3. Set the time on the front panel if needed.

Scald risk and thermostatic mixing valves

Navien · NWP500 series

Hot water can scald even at a low tank setting. Thermostatic mixing valves at each point of use lower this risk.

  1. Install thermostatic mixing valves (field supplied) at each point of use, per local code.
  2. If unsure whether the mixing valves are installed and set correctly, consult a qualified professional.

Scald risk with recirculated hot water

Navien · ComfortCirc recirculation system

Operating the water heater at high temperature sends hot water through the recirculation loop, which can scald. Install thermostatic mixing valves at each point of use to reduce the risk.

  1. Install a thermostatic mixing valve at each point of use.

Seismic bracing requirement (California)

Navien · NWP500-50, NWP500-65, NWP500-80

California law requires new, replacement and existing residential water heaters to be braced, anchored or strapped against earthquake falling or horizontal movement, at minimum per the California Plumbing Code or Section 17958.5 as amended locally.

  1. Brace, anchor or strap the water heater per the California Plumbing Code or local amendment.
  2. Use the California seismic guidelines for residential water heaters where applicable.

Servicing controls

Navien · All NPN models

Wiring errors during control service can make the heater operate improperly or dangerously.

  1. Label all wires before disconnecting them.
  2. Verify proper operation after servicing the controls.
  3. Use only approved replacement or accessory parts.

Soldering near heater connections

Navien · NWP500 series

Inlet and outlet fittings have non-metallic parts that can be damaged by heat. Solder away from the unit.

  1. Do not solder pipes while they are attached to the water heater.
  2. Solder a short length of pipe to a threaded adapter using 95/5 tin-antimony solder or an equivalent.
  3. Attach the adapter to the heater after soldering.
  4. Keep wet rags on the heater connections while soldering the home's pipes.

Starting recirculation from the NaviLink app

Navien · Manual recirculation start

Recirculation can also be started through the NaviLink app, in addition to push buttons.

Top vs side connections and heat traps

Navien · NWP500 series

Use only top or only side inlet and outlet connections, and cap the unused ones. Top connections have built-in heat traps. Side connections do not.

  1. Pick top or side connections for the cold and hot lines, not both.
  2. Cap all unused inlets and outlets to prevent leaks.
  3. If the side connection is used and local code requires a heat trap, install a heat trap nipple, insert, or piping per code.

Turn off power before installing the H2Air

Navien · H2Air add-on controller installation

Shut off power to the water heater before mounting the add-on controller. Electrical shock can cause severe injury or death.

  1. Turn off power to the water heater.
  2. Confirm power is off before installing the device.

Turning the remote controller on or off

Navien · NR-21DU remote controller

Press the Power button to switch the controller on or off. When it is on, the display lights, the LED glows green and the current hot water temperature is shown. The backlight stays on for 8 seconds after any button press.

  1. Press the Power button to turn the controller on or off.
  2. Check that the LED is green and the set temperature shows on the display when it is on.

Vent and intake inspection

Navien · All NPN models

Venting faults can cause fire or carbon monoxide poisoning. Inspect the vent termination and air intake every year.

  1. Inspect the vent termination and air intake supply annually.
  2. Turn off and stop using the heater if any vent pipe, vent elbow or intake pipe is damaged, separated at a joint, or shows corrosion, rust or melting.
  3. Do not operate the heater without proper venting.
  4. Keep combustibles, hair spray and other compressed gases away from the heater and vent termination.

View error history

Navien · NWP500-50, NWP500-65, NWP500-80

The panel keeps a list of the 10 most recent errors, newest at the top.

  1. Press and hold Menu for more than 5 seconds.
  2. Select Error History.
  3. Scroll the list with Up/Down and press OK on an error to see its details.

View or delete a weekly schedule

Navien · NWP500 weekly schedule

Review the saved schedules or remove one from the list.

  1. From the Schedule menu, select Weekly List.
  2. Scroll with Up or Down and select a schedule to view its operation mode, time, temperature and selected days.
  3. To delete, select the schedule and press OK.
  4. On the Weekly Delete screen, select Yes and press OK to delete, or select No to keep it.

Water exposure and flood damage

Navien · NWP500-50, NWP500-65, NWP500-80

If wiring, the thermostat or surrounding insulation gets wet, shut off the water heater at once and have it inspected by a qualified professional. If the unit was submerged in flood water, or the thermostat was submerged, replace the entire unit.

  1. Turn off the water heater immediately if water reaches the wiring, thermostat or insulation.
  2. Have a qualified professional inspect the unit.
  3. Replace the whole unit if it was submerged or the thermostat was submerged.

Water exposure to electrical parts

Navien · NWP500-50, NWP500-65, NWP500-80

Water near the wiring, thermostat or insulation is a serious hazard.

  1. If wiring, thermostat or insulation gets wet, turn the water heater off immediately.
  2. Have a qualified professional inspect the unit before it is run again.
  3. If the unit was submerged in flood water, or the thermostat was submerged, replace the entire unit.
  4. Confirm the unit stays dry during routine inspections.

Wiring multiple push button switches

Navien · Wired HotButton switches on the HotButton controller

Several switches can share the same HotButton terminals or run on a common branch.

  1. Connect each switch either directly to the same controller terminal or to a common branch circuit run from the controller.
  2. Connect no more than 10 push button switches to one HotButton controller.
  3. Use UTP cable or cable larger than AWG 24.
  4. Keep total cable length at or below 328 feet (100 meters).

Wiring parts supplied and external pump cable

Navien · H2Air wiring and external pump connection

The kit includes an outdoor sensor and a flow switch. Thermostat wiring is 18 AWG. An external pump connects directly to the water heater PCB with the Navien External Pump Cable.

  1. Use 18 AWG cable for thermostat wiring.
  2. Connect an external pump directly to the water heater PCB using the Navien External Pump Cable (GXXX001319).

Antifreeze in the heating system

Viessmann · Vitocell 100-V CVWC

Any glycol or antifreeze used in the heating system must be non-toxic or food grade. Give the owner a copy of the Safety Data Sheet. Viessmann Tyfocor-HTL is recommended for the solar circuit.

  1. Select a non-toxic or food grade antifreeze for the system fill.
  2. Give the owner or operator a copy of the Safety Data Sheet.
  3. Use Tyfocor-HTL for the solar heating circuit if solar fill is needed.

Avoid overtightening the tank adaptors

Viessmann · All Vitocell 100-V CVWC sizes

Overtightening can crack the glass lining on the potable side or damage the gasket on the heating side. Either one voids the warranty.

  1. Tighten BSPT adaptors until snug, and do not overtighten them.
  2. Tighten G adaptors until snug, and do not overtighten them, to protect the gasket.

Do not wrap insulating tape around the temperature sensor

Viessmann · Vitocell 100-V CVWC DHW tank temperature sensor

Insulating tape on the tank temperature sensor affects its reading. Manual says never to do it.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.