Other: Boiler tips (part 34 of 45)
Short, practical technician tips on other for boiler. Check each one against the manual for your exact model before acting.
Static-sensitive components
Viessmann · Versatronik 10.WB1 control board
Static discharge can damage components inside the control.
- Eliminate static build-up before handling or working inside the control.
Static-sensitive electronics
Viessmann · Versatronik COMO OT room controller
The control contains static-sensitive components that can be damaged by careless handling. Take anti-static precautions when working inside the control.
- Minimise static build-up before touching the inside of the control.
Status light meaning on the gateway
Viessmann · Versatronik 515 gateway
The gateway status light shows communication state. Flashing means communication is on. Solid or off means there is no communication.
- If the light is solid or off, check the gateway power and the BACnet/LON and control cabling.
Subscriber check timing
Viessmann · Vitocontrol-S cascade participant check
Re-entering the subscriber check too soon shows No Subscriber. Wait some time before trying again, because devices can take a while to report back.
- Wait, then re-enter the Subscriber Check.
Summary of system versions 1 to 10 and installation notes
Viessmann · All system versions 1 to 10
The manual lists ten heating system designs with boiler types such as Vitorond 200 and Vitocrossal 200/300. The drawings are simplified concepts only. Piping and components must be verified in the field, and a low water cut off (LWCO) must be fitted where local codes require it. The heating contractor is responsible for field installation and function.
- Pick the system version that matches the boiler type and piping layout.
- Verify the piping and all components in the field.
- Install a low water cut off where required by local codes.
Summer mode (DHW only)
Viessmann · DHW only operating program
Summer mode uses the DHW only operating program. Central heating is off, and the boiler stays available for DHW heating.
Summer mode switch function
Viessmann · Vitotronic 100 KW10B
In the up (summer/winter) position the thermostat terminal can call for heat, DHW works and outdoor reset works if programmed. Outdoor reset follows the warm weather shut-down setting. In the down (summer/DHW) position the thermostat call for heat is disabled.
- Set the summer mode switch up for normal winter heating calls.
- Set the switch down to block room thermostat heat calls while keeping DHW.
Summer mode switch positions
Viessmann · Vitotronic 100 KW10B
Up (summer/winter) lets the thermostat call for heat, DHW and outdoor reset. Down (summer/DHW) disables the thermostat heat call. With an outdoor sensor and internal outdoor reset or OpenTherm thermostat, the control starts calculating boiler water temperature at 37 °F (3 °C) outdoor and below, and the pump runs continuously.
Summer mode: heating off, DHW on
Viessmann · Summer operation of the boiler
In warm months heating can be switched off while DHW heating continues. Central heating is off and only the DHW heating remains in operation.
- Select the DHW operating program set to On.
- Select Standby mode for the heating operation.
- Confirm that DHW heating still runs and central heating is off.
Summer stand-by and exercise timer
Viessmann · Vitotron 100 VLN2
Keep power on during summer and leave the controller in stand-by between heating seasons. The exercise timer runs the pump for 15 minutes each day to prevent debris buildup.
- Do not shut off the 120VAC or 240VAC power supply between heating seasons.
- Leave the controller in stand-by (summer) mode.
- Confirm the pump exercise cycle runs about 15 minutes each day.
Support and brace the vent system
Viessmann · All vent installations
The boiler is not designed to carry the weight of the vent system.
- Support the vent system with a suitable support system for its weight and design.
- Brace the installation to keep it stable.
- Secure PP(s) termination elbows as the manufacturer specifies.
Switch increased DHW hygiene off
Viessmann · DHW tank without temperature switch
Stops the scheduled high-temperature DHW heating cycle.
- Open the DHW settings from the home screen.
- Select 'Hygiene function'.
- Deselect the highlighted day, or every day.
- Confirm.
Switch increased DHW hygiene on
Viessmann · DHW tank without temperature switch
Heats the DHW tank above 140°F (60°C) once a week or for an hour every day, at the set start time. Not valid for systems with a DHW tank with a temperature switch (e.g. Aquastat).
- Open the DHW settings from the home screen.
- Select 'Hygiene function'.
- Set the starting time under 'Start'.
- Select the required day, or every day. The selection is highlighted.
- Confirm.
Switch on the access point for communication module licences
Viessmann · Communication module
The access point lets a phone or PC reach the online legal information, such as open source licences. The WiFi credentials are on the label on the control unit.
- Open Settings, then 'Internet', then 'Access point'.
- Select 'ON' and confirm.
- Follow the instructions in the mobile app.
- Connect a phone or PC to the WiFi network 'Viessmann-<xxxx>' and enter the WiFi password.
- Open http://192.168.0.1 in a browser and follow the 'Open Source Components Licences' link.
Switch the display off for cleaning
Viessmann · Control panel
The display is deactivated for 30 seconds to prevent accidental operation. Clean it with a microfiber cloth.
- Open Settings.
- Select 'Clean screen'.
- Clean the display during the 30-second countdown.
System example 08 overview
Viessmann · System example 08
Cascade control of up to eight OpenTherm boilers over CAN bus. The heating system manager sets the boiler set point and the boilers modulate to reach it. Includes outdoor reset, common supply sensor, low loss header or hydraulic separator, DHW production and DHW recirc pump. No space heating control in this example. The common supply pump is run from the heating system manager.
System example 09 overview
Viessmann · System example 09
Cascade control of OpenTherm boilers 1 to 8 with the boiler set point from the heating system manager. Includes outdoor reset, a dry contact demand for standby boiler and boiler pump, primary side LLH or hydraulic separator pump on multifunction 3, DHW production from the secondary side header, DHW recirc pump on multifunction 4, two heating circuits with mixing valves and optional remote controls for both mixing valves.
System example 11 overview (0-10 V controller)
Viessmann · System example 11
Boiler operation is set by a 0-10 VDC signal from the heating system manager, and that signal sets the boiler temperature set point. Includes outdoor reset, primary side LLH or hydraulic separator pump on multifunction 3, DHW production from the secondary side header, DHW recirc pump on multifunction 4, two heating circuits with mixing valves, and optional remote controls for both mixing valves.
System layout 1: direct heating circuit with integrated DHW
Viessmann · Vitodens 222-F B2TB, integrated DHW, radiator circuit
Boiler feeds one radiator (high-temperature) circuit directly and makes domestic hot water in the integrated tank. Use this layout only when the heating circuit flow stays below the boiler's maximum water flow rate.
- Confirm the heating circuit flow is below the boiler maximum flow rate listed on page 30.
- If flow is above that limit or unknown, add a low-loss header (see system layout 2).
- Wire the boiler pump, DHW circulating pump and outdoor sensor as shown in the layout legend.
System layout 2: low-loss header when heating flow is high
Viessmann · Vitodens 222-F B2TB, radiator circuit with high flow
Used when the heating circuit flow is greater than the boiler's maximum water flow rate. The low-loss header is a separate accessory and includes a Viessmann temperature sensor and a heating circuit pump.
- Install the low-loss header (accessory) between boiler and heating circuit.
- Fit the Viessmann temperature sensor to the low-loss header.
- Check the heating circuit pump and boiler pump are wired as shown in the legend.
- Keep the pressure relief valve outlet piped to a suitable drain.
System layout 3: underfloor heating with system separation
Viessmann · Vitodens 222-F B2TB, underfloor heating (low-temperature circuit)
Underfloor heating with a 3-way mixing valve and a plate heat exchanger for system separation. Required when the underfloor tubing is non-oxygen diffusion barrier type.
- Install a plate heat exchanger to separate the underfloor circuit from the boiler water when using non-oxygen diffusion barrier tubing.
- Make sure all components on the secondary side of the heat exchanger are corrosion-resistant.
- Install the accessory kit for the heating circuit with mixing valve and fit the mixing valve temperature sensor.
- Use a low-loss header if the system water flow rate is unknown.
System layout 4: radiator and underfloor circuits together
Viessmann · Vitodens 222-F B2TB, mixed radiator and underfloor circuits
Combines a direct radiator circuit with an underfloor circuit that uses a mixing valve. The radiator circuit flow must be at least 30% higher than the underfloor circuit flow.
- Verify the radiator circuit flow is at least 30% greater than the underfloor circuit flow.
- Verify the combined flow of both circuits is below the boiler maximum flow rate on page 30; otherwise use a low-loss header.
- Install the accessory kit for the mixing valve and the mixing valve temperature sensor.
System layout 8: three zone circuits with DHW
Viessmann · Vitodens 222-F, three zone circuits
Three zone circuits fed from a low-loss header, with zone circuit outputs on the AM1 extension module (accessory) and one zone circuit on the boiler's own output.
- Install the AM1 extension module (accessory) for zone circuits 2 and 3.
- Connect the thermostats for zone circuits 1, 2 and 3 to their outputs as shown in the legend.
- Use a low-loss header where the total flow exceeds the boiler maximum.
- For underfloor zones, install a 3-way mixing valve kit and use system separation with non-oxygen diffusion barrier tubing.
System layouts 5 to 7: combined circuits and low-loss header
Viessmann · Vitodens 222-F B2TB, multiple heating circuits
Layouts with two or more heating circuits, some with mixing valves, where total flow can exceed the boiler maximum. A low-loss header is strongly recommended in these layouts.
- Calculate the total flow of all heating circuits and compare with the boiler maximum on page 30.
- Install a low-loss header (accessory) if the total flow exceeds the boiler maximum.
- For layout 6, install a plate exchanger for system separation on the underfloor side.
- For layout 7, connect the Vitotronic 200-H HK1B controller for the extra circuit and the AM1 extension module as needed.
Technical literature that must stay with the boiler
Viessmann · Vitorond 200 VD2 boilers
Leave all literature at the site and tell the owner where it is kept. The set includes the technical data manual, installation instructions, service instructions, operating instructions, control manuals and any other Viessmann product instructions used.
Telephone switch to force heating mode
Viessmann · Versatronik 200 heating circuits
A short between the remote control terminals switches the heating circuit to heating mode and activates DHW if fitted. When the short is removed, the controller goes back to its set program.
- Connect the switch to terminal 6 with GND at HC1, or to terminal 13 with GND at HC2.
- If a remote control is used, connect the switch at the operating module.
Temperature tempering valve in DHW supply
Viessmann · DHW supply piping
Viessmann strongly recommends a temperature tempering valve in the DHW supply line.
- Install a temperature tempering valve in the DHW supply line.
Temperature units
Viessmann · Vitocrossal 300 CA3B
Switches the display between metric and imperial units.
- From the home screen, select Settings.
- Select Temperature units.
- Select Metric or Imperial.
- Confirm.
Terminal designations must not be changed
Viessmann · Switching Module-V
Do not change the designation of the connections to the Switching Module-V terminals.
Terminology: set temperature and actual temperature
Viessmann · Vitotronic 200 display values
Set temperature is the target value to be reached, for example the set boiler temperature. Actual temperature is the value at the time of the scan, for example the actual boiler temperature.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.