Access & passwords: Water Heater tips
Short, practical technician tips on access & passwords for water heater. Check each one against the manual for your exact model before acting.
Open remote controller service settings menu
Daikin · Remote controller
Opens the service menu so Field Settings can be reached.
- Press and hold the Cancel button for 4 seconds or more.
- Select Field Settings in the Service Settings menu and press Menu/OK.
Enter the Setting menu
Navien · NWP500 all operating modes
Hold the Menu button to reach the Setting menu.
- Press and hold the Menu button for more than 5 seconds.
- Select Setting.
- Scroll with Up or Down, and press OK to select an item.
- Press Back to return to the previous screen.
Entering the Installer Menu
Navien · NWP500-50, NWP500-65, NWP500-80 display
Press and hold Menu and Back together for more than 5 seconds, then choose 1. Installer Menu. Enter the four-digit password with Up/Down to change digits and OK to move on. Factory default password is 1234. Ten wrong tries or one minute without input returns the unit to Normal mode.
- Press and hold Menu and Back together for more than 5 seconds.
- Select 1. Installer Menu.
- Enter the four-digit password using Up/Down and OK.
- Press OK after the fourth digit to confirm.
- If the password is wrong 10 times or idle for 1 minute, the unit returns to Normal mode.
Installer Menu password lockout
Navien · NWP500 series
Entering the wrong installer password 10 times, or making no input for 1 minute, returns the unit to Normal mode.
- Enter the Installer Menu password carefully.
- Use the Back button to return to the previous screen or menu.
Lock mode on/off
Navien · NPN outdoor models with remote controller
Lock mode stops accidental or child button presses. Error resets and changing settings from the front panel still work while locked.
- Press and hold the Lock button for 2 seconds to turn Lock mode on or off.
- When active, the lock icon shows and all buttons except Lock are disabled.
Open the Installer Menu
Navien · ComfortCirc installer menu
The installer menu is protected by a four-digit password. The factory default is 1234.
- Press and hold the Menu and Back buttons together for more than 5 seconds, then select Installer Menu.
- Use Up or Down to change each digit and OK to move to the next digit.
- Press OK after the fourth digit to confirm.
- After 10 wrong password entries, or 1 minute with no input, the water heater returns to Normal mode.
- Press Back to go to the previous mode.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.