Navien Tankless Water Heater: Hot water is cold or turns cold and stays cold
Hot water is cold or turns cold and stays cold on a Navien tankless water heater: Water from the hot tap stays cold or goes cold during use.
Applies to: NPN indoor and outdoor models
Common causes of hot water is cold or turns cold and stays cold
- Cold water inlet filter is clogged
- Hot tap flow is too low (less than about 0.5 GPM)
- An error code is showing
- Check valve missing on external recirculation return line
How to fix hot water is cold or turns cold and stays cold: step by step
- Clean the cold water inlet filter (page 19).
- Open the hot water faucet completely.
- Check for an error code and look it up on page 22.
- If an external recirculation system is installed, make sure there is a check valve on the return line.
If the unit shows an error code, look it up: Navien Tankless Water Heater codes
Source: Navien NPN user's information manual, p. 21. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.