Navien General: Replacing the temperature sensor

Updated · by Aurora Star Tech Inc.

Replacing the temperature sensor on a Navien general: Temperature sensor is held to the T-adapter by 2 screws.

Homeowner with a heating or cooling system problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: WEC600

How to fix replacing the temperature sensor: step by step

  1. Shut off the feedwater supply.
  2. Disconnect power to the WEC.
  3. Remove the back cover (see Removing the Back Cover, p. 82).
  4. Remove the 2 screws from the T-adapter that hold the temperature sensor.
  5. Unplug the temperature sensor connector from the harness and remove the sensor from the T-adapter.
  6. Install the new temperature sensor and connect it to the harness.
  7. Secure the temperature sensor to the T-adapter with 2 screws.
  8. Put the back cover on and secure it with 11 screws.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien General codes

Source: Navien WEC Series service manual, p. 109-110. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.