Navien General: Replacing the freeze prevention solenoid valve
Replacing the freeze prevention solenoid valve on a Navien general: Remove the back cover, disconnect the valve and hoses, then fit the new solenoid valve and reconnect it.
Applies to: WEC600
How to fix replacing the freeze prevention solenoid valve: step by step
- Turn off the feedwater supply.
- Disconnect power to the WEC.
- Remove the back cover (see page 82).
- Remove the 2 screws holding the freeze prevention solenoid valve and pull the valve out.
- Unplug the connector from the solenoid valve.
- Remove the 2 clips and detach the hoses from the solenoid valve.
- Connect the hoses to the new solenoid valve and secure the 2 clips.
- Plug the harness connector into the solenoid valve.
- Place the valve on the water treatment system and fasten it with 2 screws.
- Reinstall the back cover and secure it with 11 screws.
If the unit shows an error code, look it up: Navien General codes
Source: Navien WEC service manual, p. 96. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.