Navien General: Replacing the circulation pump
Replacing the circulation pump on a Navien general: The circulation pump is grounded to the WEC case and connected through the harness.
Applies to: WEC600
How to fix replacing the circulation pump: step by step
- Turn off the feedwater supply and disconnect power
- Remove the 2 screws from both sides of the front cover and remove the cover
- Remove the screw that holds the ground wire to the WEC case
- Remove the circulation pump connector from the harness
- Replace the pump and reassemble in reverse order
If the unit shows an error code, look it up: Navien General codes
Source: Navien WEC600 service manual, p. 88. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.