Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien General: Replacing the chlorine tablet pouch holder assembly

Updated · by Aurora Star Tech Inc.

Replacing the chlorine tablet pouch holder assembly on a Navien general: Swap the pouch holder in the sediment pre-filter housing. Use the pouch holder that matches the supply pipe size.

Homeowner with a heating or cooling system problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: WEC600 (sediment pre-filter housing)

How to fix replacing the chlorine tablet pouch holder assembly: step by step

  1. Close the inlet and outlet valves.
  2. Open the bypass valve.
  3. Release pressure from the filter by pressing the red pressure release button on the sediment pre-filter housing cover. If there is no release button, close the bypass valve, open the outlet valve and the nearest cold water faucet, then close the outlet valve, open the bypass valve and close the faucet once pressure is released. Do not drain all the plumbing water.
  4. Remove the sediment pre-filter housing with the filter housing wrench.
  5. Check that a chlorine tablet is in the tablet pouch of the kit. If not, contact Technical Support.
  6. Check the supply pipe size (1 in. or 3/4 in.) and select the matching pouch holder.
  7. Insert the pouch holder assembly into the sediment pre-filter housing cover, aligned with the IN marking on the water inlet.
  8. Center the cartridge in the filter housing and tighten with the filter housing wrench.
  9. Close the bypass valve and open the inlet and outlet valves.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien General codes

Source: Navien WEC service manual, p. 117-118. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.