Navien General: Replace the post carbon block (C/B) cartridge

Updated · by Aurora Star Tech Inc.

Replace the post carbon block (C/B) cartridge on a Navien general: Procedure for changing the post carbon block filter. Replace about every 6 months, or sooner based on water quality or flow loss.

Homeowner with a heating or cooling system problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: WEC Series post carbon block (C/B) filter

Common causes of replace the post carbon block (c/b) cartridge

  • Flow or pressure loss at fixtures may mean the cartridge needs changing before the indicator comes on.
  • Water quality can shorten cartridge life.

How to fix replace the post carbon block (c/b) cartridge: step by step

  1. Unplug the WEC power cord (power off). An error will block filter replacement if power is still on.
  2. Close the inlet and outlet valves.
  3. Open the bypass valve.
  4. Press the red pressure release button on the post C/B housing cover. If there is no button, use the same bypass, outlet and faucet method described for the sediment filter.
  5. Unscrew the housing with the filter housing wrench.
  6. Remove and discard the used cartridge.
  7. Clean inside the housing.
  8. Install the new cartridge with the top gaskets in place and centered, then tighten.
  9. Close bypass and outlet valves, then open inlet and service valves.
  10. Press the red pressure release button to purge air.
  11. If flushing through the service line, open the service valve and drain for 3 minutes. The cartridge may release fine black powder during this first flush.
  12. Close bypass and service valves, then open inlet and outlet valves.
  13. Plug the power cord in. The WEC starts Auto Flushing and then goes to standby.
  14. Reset the post C/B filter use period: press and hold Back, OK and Next for 3 seconds (see 3.7, p. 36).
  15. Keep the inlet and outlet plugs in place until installation. Do not leave internals exposed to air for more than 4 hours.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien General codes

Source: Navien WEC Series Service Manual, p. 44-45. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.