Navien General: Replace the freeze prevention solenoid valve
Replace the freeze prevention solenoid valve on a Navien general: Replacement procedure for the freeze prevention solenoid valve on the WEC600. Work from the back of the unit with the feedwater off and power disconnected. Remove the back cover first (see page 82 of the manual, not included in this extract).
Applies to: WEC600
How to fix replace the freeze prevention solenoid valve: step by step
- Turn off the feedwater supply.
- Disconnect the power supply from the WEC.
- Remove the back cover from the WEC.
- Remove the 2 screws holding the freeze prevention solenoid valve and pull the valve out.
- Disconnect the valve connector.
- Remove the 2 clips and detach the hoses from the valve.
- Connect the hoses to the new valve and secure with the 2 clips.
- Connect the harness connector to the new valve.
- Set the valve in place and secure with the 2 screws.
- Put the back cover on and secure with 11 screws.
If the unit shows an error code, look it up: Navien General codes
Source: Navien WEC service manual, p. 96. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.