Navien General: Removing the flow sensor housing, product/regeneration pipe and side frame brackets

Updated · by Aurora Star Tech Inc.

Removing the flow sensor housing, product/regeneration pipe and side frame brackets on a Navien general: Disassembly of the flow sensor, water pipe assembly and side frame before NDI module work.

Homeowner with a heating or cooling system problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: WEC600

How to fix removing the flow sensor housing, product/regeneration pipe and side frame brackets: step by step

  1. Remove the 4 screws fixing the flow sensor housing to the NDI modules.
  2. Remove the 4 clips from the Y-adapters and the circulation pump outlet hose.
  3. Detach the circulation pump outlet hose.
  4. Remove the product/regeneration water pipe assembly from the WEC.
  5. Keep the O-rings on the adapters intact; do not lose or damage them.
  6. Remove the 4 screws from the side frame brackets.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien General codes

Source: Navien WEC service manual, p. 112. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.