Navien General: Reinstalling the product/regeneration pipe and flow sensor housing
Reinstalling the product/regeneration pipe and flow sensor housing on a Navien general: Refit the water pipe assembly and flow sensor after NDI module replacement.
Applies to: WEC600
How to fix reinstalling the product/regeneration pipe and flow sensor housing: step by step
- Insert the O-ring into the Y-adapter and install the product/regeneration water pipe assembly.
- Connect the circulation pump outlet hose to the pipe assembly.
- Install the 4 clips on the hose and Y-adapters.
- Secure 4 screws to fix the flow sensor housing to the NDI modules.
If the unit shows an error code, look it up: Navien General codes
Source: Navien WEC service manual, p. 114. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.