Navien General: Refill the CIP solution
Refill the CIP solution on a Navien general: Refill the CIP tank with citric-acid-based Navien CIP solution when the CIP icon blinks. Refill about every 6 months, or sooner based on water quality and usage.
Applies to: WEC Series CIP tank
Common causes of refill the cip solution
- Low CIP solution means CIP will not work properly, water quality is not guaranteed, and flow drops.
How to fix refill the cip solution: step by step
- Wear proper PPE and follow the CIP solution safety data sheet.
- Remove the screws on both sides of the front cover and take off the cover.
- Remove the lid from the CIP tank.
- Insert a funnel into the tank inlet.
- Pour CIP solution slowly through the funnel to avoid spills.
- Remove the container and close the tank lid.
- Close the front cover and tighten both screws.
- Reset the CIP fill level: press and hold Back, OK and Next for 3 seconds (see 3.7, p. 36).
- Clean the funnel after use. Do not use any cleaner other than citric acid in the CIP tank.
If the unit shows an error code, look it up: Navien General codes
Source: Navien WEC Series Service Manual, p. 46-47. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.