Navien General: Pre-treatment filters for poor feedwater
Pre-treatment filters for poor feedwater on a Navien general: Extra filtration is required when turbidity or iron is above the limits. The sediment pre-filter must sit on the point-of-entry line ahead of the WEC.
Applies to: WEC600
Common causes of pre-treatment filters for poor feedwater
- Turbidity above the EPA standard
- Total iron above 0.3 ppm
How to fix pre-treatment filters for poor feedwater: step by step
- If turbidity exceeds the EPA standard (≤ 0.3 NTU at 95% and ≤ 1 NTU), install an extra filter upstream of the sediment pre-filter.
- If total iron is over 0.3 ppm, install an iron filter before the sediment pre-filter.
- Install the sediment pre-filter on the POE line before the WEC.
- Do not connect the sediment pre-filter directly to the WEC inlet.
- Confirm the sediment pre-filter and post carbon block filter are installed correctly.
If the unit shows an error code, look it up: Navien General codes
Source: WEC Series service manual, p. 16. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.