Installing the post carbon block (C/B) filter on a Navien general: Mount and fit the post carbon block filter at the rear of the product water outlet.
Applies to: WEC600
How to fix installing the post carbon block (c/b) filter: step by step
- Unscrew the filter housing from the head using the supplied wrench.
- Fix the mounting bracket to the top of the housing head with screws (B).
- Mount the bracket to the wall with screws (A), at least 2 ft (635 mm) above the floor.
- Insert the cartridge into the housing and tighten the head with the supplied wrench.
- Remove the quick guide from the filter first, or pressure loss and low flow will result.
- Stick the Carbon Block Filter (Outlet) label on the bracket.
If the unit shows an error code, look it up: Navien General codes
Source: Navien WEC service manual, p. 18. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.