Navien General: Draining the water from the WEC
Draining the water from the WEC on a Navien general: Drain the unit through the drain connector on the inlet water pipe assembly.
Applies to: WEC600
How to fix draining the water from the wec: step by step
- Remove the front cover (see front cover procedure)
- Disconnect the clip and end plug from the drain connector of the inlet water pipe assembly
- Connect the drain hose to the drain connector
- Wait until the water is fully drained from the WEC
- Reassemble in reverse order
If the unit shows an error code, look it up: Navien General codes
Source: Navien WEC600 service manual, p. 81-82. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.