Navien Furnace: Vent termination placement
Vent termination placement on a Navien furnace: The termination must be at least 12 in (300 mm) above ground, at least 12 in above the highest expected snow level, or meet local code, whichever is greater. Keep intake and exhaust terminations clear of obstructions.
Applies to: Direct and non-direct vent termination
Common causes of vent termination placement
- Termination too close to snow level or ground
- Obstruction near the terminal
How to fix vent termination placement: step by step
- Confirm the termination height is at least 12 in above ground and above the expected snow level.
- Use the greater of that height or the local code requirement.
- Keep the exhaust termination at least 12 in from the intake air inlet in a non-concentric layout.
- Keep at least 12 in clearance from any obstruction above, below, left or right of the terminal.
- Keep the intake pipe as short as practical.
- Do not terminate above a sidewalk or driveway in the restricted case noted on page 66.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 72. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.