Navien Furnace: Upflow vent and drain layout options
Upflow vent and drain layout options on a Navien furnace: Upflow furnaces can exit the vent at the top or left side, with the condensate drain on the left or right and either internal or external trap mounting. Pick the combination shown in Figure 16 that fits the site. Intake is optional.
Applies to: NDF upflow installations
How to fix upflow vent and drain layout options: step by step
- Choose the vent exit (top or left) and drain side (left or right) from Figure 16.
- Choose internal or external trap mounting to suit the cabinet and clearances.
- Confirm the intake route if a separate intake is used.
- Route and secure the drain hoses and pressure switch tubing to match the chosen layout.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NDF Installation and Operation Manual, p. 40. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.