Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Navien Furnace: Supply air temperature sensor fault (open or short)

Updated · by Aurora Star Tech Inc.

Supply air temperature sensor fault (open or short) on a Navien furnace: When the supply air sensor reads open or short, the furnace drops to Emergency heat mode and keeps heating.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Supply air control mode

Common causes of supply air temperature sensor fault (open or short)

  • Supply air temperature sensor is open.
  • Supply air temperature sensor is shorted.

How to fix supply air temperature sensor fault (open or short): step by step

  1. Confirm the furnace is in Emergency heat mode.
  2. Replace the supply air temperature sensor.
  3. Verify the furnace returns to Normal operation and runs a heating cycle.
  4. In Emergency heat mode, the coil water target is 140°F (60°C) and airflow stays on normal control.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Furnace codes

Source: Navien NPF installation and operation manual, p. 97. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.