Navien Furnace: Selecting approved vent pipe materials
Selecting approved vent pipe materials on a Navien furnace: Venting rules differ in the US and Canada. Use approved materials only and never mix pipe types, as this can leak flue gas into the living space and void the warranty and certification. The default vent pipe material set for this product is Schedule 40 PVC.
Applies to: Vent pipe and fitting selection
Common causes of selecting approved vent pipe materials
- Mixing vent pipe materials
- Using unapproved cellular core PVC or CPVC, or Radel, for exhaust
How to fix selecting approved vent pipe materials: step by step
- Use only approved vent materials for the locale (USA or Canada).
- Do not use cellular core PVC (ASTM F891), cellular core CPVC or Radel (polyphenolsulfone) for the exhaust vent.
- Do not use Schedule 40 or 80 polypropylene water or waste pipe in the vent run.
- Do not mix vent systems or manufacturers within a run.
- Use only the listed terminations from the same manufacturer as the vent system.
- For Canada, field-supplied plastic vent must be certified to ULC-S636 and come from one system manufacturer.
- Follow the vent manufacturer's instructions for installation details.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 69-71. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.