Navien Furnace: Return air ductwork sealing and joist space safety
Return air ductwork sealing and joist space safety on a Navien furnace: Poor sealing or gas piping in return joist spaces can pull combustion products into the living space.
Applies to: NDF600 series furnaces
Common causes of return air ductwork sealing and joist space safety
- Return air joist space shared with plumbing stacks or chimney components
- Return air ductwork not sealed to the furnace
- Flue products entering supply or return ductwork
How to fix return air ductwork sealing and joist space safety: step by step
- Do not route gas piping through joist spaces used for return air.
- Do not use a joist space for return air if it holds plumbing stacks or chimney parts, unless the return portion is fully isolated.
- Seal all return air ductwork to the furnace with sheet metal screws.
- Tape the sheet metal seams near the furnace with duct tape or similar material.
- If the furnace sits on a platform with bottom return, seal it airtight between the furnace and the return plenum.
- Support the platform solidly so it does not sag, and seal between the support and the base.
- Make sure flue products cannot enter the return or supply ductwork.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NDF Forced Air Gas Furnace Installation and Operation Manual, p. 17. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.