Navien Furnace: Protecting the furnace from freeze damage during outages or long shutdown
Protecting the furnace from freeze damage during outages or long shutdown on a Navien furnace: Power failures in cold weather stop the freeze prevention system, which can freeze the heat exchanger.
Applies to: NPF furnace shutdown and freeze protection
Common causes of protecting the furnace from freeze damage during outages or long shutdown
- Loss of power disables the freeze prevention system
- Extended outage in cold area
How to fix protecting the furnace from freeze damage during outages or long shutdown: step by step
- In cold areas with frequent outages, drain the furnace completely during long outages by emptying the water tank (see section 7.4 on page 142).
- Disconnect the power supply to the furnace when it will not be used for a long period.
- Optionally use a battery back-up to supply heat during short outages.
- Note that freeze damage is not covered under warranty.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 77. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.