Navien Furnace: Propane gas supply and piping
Propane gas supply and piping on a Navien furnace: Propane pressure and piping checks from the manual.
Applies to: NPF700 hydro-furnace propane installations
Common causes of propane gas supply and piping
- Propane odorant can fade, so a leak may not be smelled.
- Rust and soil can reduce odorant.
- Pipe dope that is not approved for propane can attack the joints.
How to fix propane gas supply and piping: step by step
- In basements, excavated areas or confined spaces, install a gas detecting warning device.
- Confirm propane pressure is 8 in WC to 13 in WC at the furnace manifold with all gas appliances running.
- Use two-stage regulation and check pressure drop between regulators and the appliance.
- Use only pipe dope approved for propane; do not use white lead compounds.
- Follow the propane tank maker's installation manual and the supplier's regulator settings.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 51. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.