Navien Furnace: Priming the condensate trap
Priming the condensate trap on a Navien furnace: The condensate trap must be full of water before the furnace starts. Priming is done through the vent drain hose at the inducer.
Applies to: NDF condensate trap
How to fix priming the condensate trap: step by step
- Remove the vent drain hose from the inducer elbow or drain fitting.
- Pour about one cup of water down the hose.
- Wait for water to run out the condensate trap outlet, which shows the trap is full.
- Reconnect the vent drain hose to the inducer elbow or drain fitting.
If the unit shows an error code, look it up: Navien Furnace codes
More commissioning tips for furnace
Source: Navien NDF Installation and Operation Manual, p. 45. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.