Navien Furnace: Preparing the vent and drain option
Preparing the vent and drain option on a Navien furnace: Choose the vent and drain option first, then prepare the inducer, vent and intake connections and the trap location.
Applies to: Upflow, downflow and horizontal orientations
How to fix preparing the vent and drain option: step by step
- Choose the vent and drain option using the inducer rotation section and Table 5.
- Remove the 3-1/2 in plastic exhaust vent cap if needed and cover any unused vent hole. Install the rubber grommet from the parts bag for the 2 in vent pipe, then connect the field-supplied vent pipe.
- If using 1-1/2 in or 3 in vent, make the transition as close to the unit as possible and on a vertical section.
- Support the exhaust vent before fitting it to the inducer. The inducer must not carry any weight of the venting system.
- Remove the air inlet cap if applicable, attach the intake fitting with gasket to the furnace panel and connect the 2 in intake pipe.
- Remove the two plastic caps on the blower division and the one on the side panel if applicable.
- Mount the condensate trap on the side panel inside or outside the blower compartment for upflow and downflow, using the two screws from the parts bag. For horizontal positions, mount it on the exterior side panels.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NDF installation and operation manual, p. 38. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.