Navien Furnace: Outdoor temperature sensor installation
Outdoor temperature sensor installation on a Navien furnace: Mount the outdoor sensor where it reads true outdoor air and is shielded from sun, heat sources and moisture.
Applies to: NPF700 60/80/100 MBH
How to fix outdoor temperature sensor installation: step by step
- Pull the sensor body out of the cap.
- Fasten the body to the wall with the supplied screws and anchors on the North or Northeast side, under eaves.
- Run the wires into the body through the grommet.
- Connect the wires to the sub controller terminal block.
- Make sure connections are tight, then attach the cap.
- Use 18 gauge thermostat wire with no splices; keep it away from line voltage and use shielded cable if needed.
- Keep the sensor away from fans, exhausts, vents and lights.
If the unit shows an error code, look it up: Navien Furnace codes
More commissioning tips for furnace
Source: Navien NPF installation and operation manual, p. 115. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.