Updated · by Aurora Star Tech Inc.

Outdoor air from attic or crawl space (Case 3) install notes on a Navien furnace: Attic air is used only if the attic is adequately vented and the opening is above the insulation.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NDF600 series furnaces with attic or crawl space air

Common causes of outdoor air from attic or crawl space (case 3) install notes

  • Attic exhaust fan creating negative pressure

How to fix outdoor air from attic or crawl space (case 3) install notes: step by step

  1. Use one opening from the floor drawing from the ventilated crawl space, and one opening that connects freely to the ventilated attic.
  2. If using attic air, duct the opening from the ceiling high enough to be above the insulation.
  3. Make sure the attic is vented with soffit or gable vents.
  4. As an option, drop a duct from the attic ending 12 in (305 mm) above the floor.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Furnace codes

Source: Navien NDF Forced Air Gas Furnace Installation and Operation Manual, p. 22. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.