Navien Furnace: Massachusetts side-wall vent requirements
Massachusetts side-wall vent requirements on a Navien furnace: Required when a side-wall horizontal vent terminates less than seven feet above finished grade. Carbon monoxide detectors and a warning sign are needed, and the installation must be done by a licensed plumber or gas fitter under 248 CMR 4.00 and 5.00.
Applies to: Side-wall horizontally vented gas appliances in Massachusetts
How to fix massachusetts side-wall vent requirements: step by step
- Install a battery or hard-wired CO detector on the same floor as the appliance, or on the next adjacent floor if the appliance is in a crawl space (not required for a detached uninhabitable garage).
- For all residential dwellings, place a CO detector on each habitable level.
- Use CO detectors that meet NFPA 720 and are ANSI/UL 2034 listed and IAS certified.
- Where a through-the-wall vent is less than seven feet above grade, mount a metal or plastic sign at least eight feet above grade, directly in line with the vent terminal.
- Sign text must read GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS, with letters at least 0.5 inch high.
- The local gas inspector must confirm CO detectors and signage are in place before approving the installation.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 181. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.