Navien Furnace: Massachusetts gas piping rules
Massachusetts gas piping rules on a Navien furnace: In Massachusetts, a licensed plumber or gas fitter must install the product. Flexible connectors may not exceed 36 in (914 mm). Lever gas shutoffs must be T-handle type. Copper gas piping is not allowed.
Applies to: NDF600 series furnaces installed in Massachusetts
How to fix massachusetts gas piping rules: step by step
- Use a licensed plumber or gas fitter.
- Keep flexible gas connectors 36 in (914 mm) or shorter.
- Use T-handle gas shutoffs.
- Do not use copper tubing for gas piping.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NDF Forced Air Gas Furnace installation and operation manual, p. 7. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.