Navien Furnace: Leak testing new gas piping
Leak testing new gas piping on a Navien furnace: Leak test all new gas piping and any section not yet pressure tested, such as from the manual shut-off valve to the furnace gas valve. Pressure test per CAN/CSA-B149.1 and 2, NFPA 54, ANSI Z223.1, or ANSI/NFPA 58.
Applies to: New gas piping and gas valve connections
How to fix leak testing new gas piping: step by step
- Pressure test new gas piping as the applicable code specifies.
- Test untested sections with an electronic combustible gas detector, a commercial leak detector, or another locally approved method.
- Never use a match, lighter, flame, or other ignition source to find leaks.
- At the furnace, use leak detection solution on the gas valve/manifold connection and burner orifices, and on pressure boss screws. Bubbles mean a leak.
- Shut off gas and repair all leaks before continuing.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NDF installation and operation manual, p. 48, 50, 52. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.