Navien Furnace: Leak testing gas piping
Leak testing gas piping on a Navien furnace: Gas piping that has not been pressure tested, such as from the manual shut-off valve to the furnace gas valve, must be leak tested. New installations should be pressure tested per CAN/CSA-B149.1 and 2, NFPA 54, ANSI Z223.1 or ANSI/NFPA 58.
Applies to: NDF gas piping
How to fix leak testing gas piping: step by step
- Pressure test new gas piping per the code named in the manual.
- Leak test any untested section from the manual shut-off valve to the furnace gas valve.
- Use an electronic combustible gas detector, a commercial leak detector, or another locally approved method.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NDF Installation and Operation Manual, p. 48. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.