Navien Furnace: Install the condensate neutralizer kit
Install the condensate neutralizer kit on a Navien furnace: Use the Navien neutralizer kit when condensate goes to a drain through neutralizing media, which raises the pH and protects the drain system and public sewer.
Applies to: NPF700 series with neutralizer disposal
Common causes of install the condensate neutralizer kit
- Local codes or the site require neutralized condensate
How to fix install the condensate neutralizer kit: step by step
- Do not let exhaust flue gases pass through the neutralizer, as this can cause carbon monoxide poisoning.
- Mount the neutralizer on a wall or floor with the brackets supplied.
- Keep the neutralizer inlet and discharge closer to the floor than the condensate drain.
- Install an overflow bypass between the appliance and the neutralizer to stop backflow into the appliance.
- If the neutralizer is horizontal, rotate it so the outlet is the highest point.
- If it is vertical, make sure the outlet is higher than the inlet.
- Use corrosion resistant piping and secure it so it does not move.
- If more than one appliance feeds the neutralizer, size it correctly for the total load.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 41. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.