Navien Furnace: Gas supply connection and leak check

Updated · by Aurora Star Tech Inc.

Gas supply connection and leak check on a Navien furnace: Gas connections must be made by a licensed professional. Size the line and check for leaks before the furnace is put into service.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NPF700 series

Common causes of gas supply connection and leak check

  • Gas meter capacity is smaller than total connected appliance load
  • Gas line not pressure tested or purged before connection

How to fix gas supply connection and leak check: step by step

  1. Confirm gas type and pressure on the rating plate.
  2. Connect the furnace as the first appliance downstream of the gas meter. Gas meter capacity must be at least the total load of all connected appliances.
  3. Pressure test the main gas supply line.
  4. Purge the gas line of debris.
  5. Size the gas line using the pipe sizing tables.
  6. Install certified full port valves on the supply line.
  7. Follow the regulator manufacturer or local code for distance from regulator to appliance.
  8. Install a manual gas shut-off valve between the supply and the furnace, and a drop leg.
  9. Use a 1/2 in gas connection. Use 1/2 in rigid pipe only within the sizing table limits. Do not use 1/2 in corrugated connectors.
  10. Install a union close to the furnace on rigid pipe for future service.
  11. Hold the furnace connector with one wrench and tighten the pipe with the other to avoid damage.
  12. Support the piping with hangers. Do not let the furnace or its accessories carry the pipe weight.
  13. Do not run a flexible gas connector inside the cabinet. Use a new listed connector only where local codes allow it, and not one that served another gas appliance.
  14. Massachusetts requires flexible connectors under 36 in.
  15. Keep flexible lines free of crimps and tight bends and sized for the required BTU load.
  16. Check all joints with a bubble test. Never use a flame.
  17. Turn off the furnace and gas supply if a leak is found, repair it, and do not restart until the leak is fixed.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Furnace codes

Source: Navien NPF installation and operation manual, p. 44-46. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.