Updated · by Aurora Star Tech Inc.

Furnace does not light after first start or gas line work on a Navien furnace: Air trapped in the gas supply line can stop the furnace from igniting during the first trial ignition after installation or after gas line work.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: All NDF furnaces

Common causes of furnace does not light after first start or gas line work

  • Air trapped in the gas supply line after installation
  • Gas line work recently done

How to fix furnace does not light after first start or gas line work: step by step

  1. Turn the thermostat down below the current set point.
  2. Wait 5 minutes.
  3. Set the thermostat to the desired setting and try again.
  4. If the problem continues, follow the shutdown procedure and call the installer, service agency or gas supplier.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Furnace codes

Source: Navien NDF installation and operation manual, p. 88. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.