Freeze protection for furnace, trap and drain on a Navien furnace: Where the furnace may reach near 32°F (0°C), such as an alcove or attic, insulate the drain trap, drain pipe and supply water line. Exposed drain piping must be protected from freezing. Heat tape or heating cable rated 3–6 W/ft that is UL or CSA listed/approved is acceptable.
Applies to: NPF700 all models
How to fix freeze protection for furnace, trap and drain: step by step
- Insulate the drain trap, drain pipe and supply water line where freezing is possible.
- Protect exposed drain piping from freezing.
- If heat tape is used, rate it at 3–6 W/ft, UL or CSA listed/approved, and install and maintain it per the maker's instructions.
- Check heat tape operation at installation.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 27. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.