Updated · by Aurora Star Tech Inc.

Duct sizing and return air limits on a Navien furnace: Ducts must match the furnace CFM and external static rating. Return air must not be restricted or taken from a small enclosed space.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: NPF700 hydro-furnace ducting

Common causes of duct sizing and return air limits

  • Closed dampers or registers.
  • Undersized or poorly laid out ductwork.
  • Return connected to the furnace back or to a room, closet or alcove.

How to fix duct sizing and return air limits: step by step

  1. Design the duct system to ACCA Manual D or NFPA 90A/90B.
  2. Use a closed return duct system connected to the furnace.
  3. Do not attach ducts to the back of the furnace.
  4. For 1800 CFM or more, use two side returns or a side plus bottom return.
  5. Do not use a room, closet or alcove as a return air chamber.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Furnace codes

Source: Navien NPF installation and operation manual, p. 51. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.