Updated · by Aurora Star Tech Inc.

Condensate drain setup and trap mounting on a Navien furnace: The furnace can make up to about 4-1/2 lb of water per hour (about 2 imperial quarts, 2-1/2 US quarts or 2-1/4 liters). Provide a drain path, and protect drains and traps from freezing in spaces that can drop below freezing.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Upflow and horizontal installations

How to fix condensate drain setup and trap mounting: step by step

  1. Mount the condensate trap on the outside of the blower compartment side panel for upflow. For horizontal positions, mount it on the exterior side panels.
  2. Use the drain hose supplied. Cut it to length for the application so it does not kink, and make sure it can reach the side panel.
  3. Secure the large plastic clamps on the front manifold cover drain outlet and on the 5/8 in barbed fitting of the trap.
  4. Secure the small plastic clamp on the inducer drain collar and on the 1/2 in barbed fitting of the trap.
  5. Tighten the clamps firmly with pliers.
  6. Angle the inducer drain holes about 15 degrees downward.
  7. Slope the drain tubing toward the trap and make sure no hose sections form a trap before the condensate trap.
  8. Push barbed fittings fully into the trap and hoses until they seat on the barb flange.
  9. Prime the condensate trap with water before the first startup.
  10. Protect drains and traps from freezing where the space can reach freezing temperatures.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Furnace codes

Source: Navien NDF installation and operation manual, p. 37-38. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.