Navien Furnace: Concentric vent terminal installation
Concentric vent terminal installation on a Navien furnace: A concentric kit lets one wall penetration handle both combustion air intake and exhaust. Use an approved IPEX kit and follow the kit maker instructions for the install.
Applies to: Concentric venting with approved IPEX kits
How to fix concentric vent terminal installation: step by step
- Use only an approved kit: 2 in IPEX kit 196005 or 3 in IPEX kit 196006.
- If 1-1/2 in vent material is used with a concentric kit, use an increaser coupling to connect to the 2 in concentric kit.
- Follow the concentric terminal manufacturer instructions for the install.
- Offset straight vertical runs so condensate is pushed against the vent walls.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NDF installation and operation manual, p. 32. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.