Navien Furnace: Choosing the installation location
Choosing the installation location on a Navien furnace: Pick a location with enough clearance, venting, drainage, and access to gas and electrical supplies. Do not install outdoors, and do not install in an RV, trailer, boat or other moving vehicle.
Applies to: NPF700 series
How to fix choosing the installation location: step by step
- Confirm the room air and ambient temperature is above 32 °F (0 °C) and below 125 °F (52 °C).
- Confirm the location is indoors and not a moving vehicle.
- Confirm at least one carbon monoxide detector is installed in the living space before start-up.
- Check local codes and the required standards (NEC, NFPA 90A/90B, CSA B149.1 in Canada).
- In Massachusetts, follow section 7.7.
If the unit shows an error code, look it up: Navien Furnace codes
Source: Navien NPF installation and operation manual, p. 24. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.