Navien Furnace: Choosing a vent terminal location

Updated · by Aurora Star Tech Inc.

Choosing a vent terminal location on a Navien furnace: Pick a termination spot where flue gas cannot pool or get pulled back into the combustion air intake, and where condensate or frost will not cause damage. Moisture leaving the terminal can freeze on walls and nearby objects, and some discoloration is normal.

Homeowner with a furnace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Direct and non-direct vent terminations

Common causes of choosing a vent terminal location

  • Flue gas recirculating into the combustion air intake
  • Condensate dripping onto walks, patios, planters or shrubs
  • Exhaust fogging or icing near windows
  • Winter winds blowing vent products back onto the terminal

How to fix choosing a vent terminal location: step by step

  1. Keep the terminal away from spots where flue gas can stagnate.
  2. Keep it clear of walkways, patios and planters where condensate will drip.
  3. Keep it away from shrubs and vegetation, and caulk all cracks, seams and joints within 6 ft (1.8 m) of the terminal.
  4. Do not put the terminal under a deck unless clearance is enough to prevent damage. Insulate any piping run under a deck and support it so condensate cannot collect and freeze.
  5. Do not put the terminal on the side facing prevailing winter winds.
  6. Keep at least 3 ft (0.9 m) from an inside corner formed by two exterior walls.
  7. For overhangs, keep at least 1 ft (0.3 m) vertical clearance for each 1 ft horizontal, up to 6 ft (1.8 m).
  8. Make sure nearby painted surfaces are in good condition. Consider sealing wood that may see flue gases.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Furnace codes

Source: Navien NDF installation and operation manual, p. 32. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.